Welcome to GT

Uranium exploration in Nanxiong, Guangdong

1525252866120101.png


The content of exploration is to explore the location and scope of uranium deposits.

Construction parameters: AB=180 m, BM1=295 m MN=15 m; the power supply voltage is 600V, the pole distance is larger, and the detection depth is about 190m~250m.

blob.pngblob.png

blob.pngblob.png

Through the above 4 graphs and combined with the relevant geological data, we can see that there are two low resistivity anomalies at the level 100m and 200m. It is speculated that the site contains uranium ore; the corresponding position in Figure 2 shows high polarization rate; the time constant parameters of Figure 3 mainly reflect the conduction degree of the underground rock to different frequency currents, and the conductivity is better.